Hall flooring

In many production halls, the floor looks good at first – but quickly becomes a cost factor: cracks, chipping, broken edges or chemical attack from coolants and cleaning agents.

The LuxTek hall flooring system therefore does not rely on a sensitive surface layer like conventional coatings, but on a **solid engineering plastic (PE-HMW/UHMW)** whose **resistance is inherent in the material itself**. This creates a flooring solution designed for real production loads: **robust under point loads, tough against impacts and vibrations, and resistant to many industrial substances** – ensuring reliable performance in three-shift operation without the need for constant repairs.

1 Products in this category | Total: 95 Items
Sorted by:

Why conventional production hall floors often fail too early

In day-to-day production, load-bearing capacity is only one factor. What really matters is the constant combination of point loads, rolling and shear forces, impacts and vibrations, as well as contact with industrial substances – and it is precisely this continuous stress that causes many flooring systems to require repairs sooner than expected.

Conventional concrete: load-bearing, but not designed for production demands

Concrete provides basic structural stability, but in practice it is often microcracks, broken edges and surface damage in heavily stressed areas that cause problems. Especially where machine feet, pallets, manoeuvring movements or dynamic load changes occur, a floor that initially appears durable can quickly become maintenance-intensive.

Coatings & epoxy: looks clean – until it is put under stress

Coatings may look excellent at first, but typical weaknesses become apparent in production environments:

  • Chipping / delamination when moisture, chemicals or mechanical loads attack edges and transitions
  • Impact sensitivity when hard impacts or falling objects occur
  • Refurbishment with downtime because substrate preparation and curing take up valuable production time

Tiles / industrial floor panels: many joints, many weak points

Joints are rarely an advantage in production environments: dirt, chemicals, edge loads and cleaning cycles all affect these areas. Once edges become damaged, the surface can quickly become uneven – which is problematic for transport, pallet trucks and workplace safety.

The difference: LuxTek production hall flooring

High compressive strength & suitable for point loads

Machines do not stand on a large flat surface, but on individual feet. Pallets create concentrated loads, and heavy components are placed directly on the floor. This is exactly what the hall flooring system is designed for: dimensionally stable under pressure and reliable under point loads – ideal for machine zones, assembly areas and material handling.

Tough and resistant to cracking under impacts & vibrations

Production means vibrations, impacts and recurring loads. Where rigid systems are prone to cracking, LuxTek relies on tough material properties – designed for continuous three-shift operation without the surface breaking down after a short period of use.

Resistant to chemicals and coolants

Coolants, oils, greases and cleaning agents are part of everyday operations in many production halls. LuxTek hall flooring is resistant to typical industrial substances – helping to avoid the common problems associated with coatings, where layers can detach at edges, transitions or damaged areas.

Who are PE-HMW/UHMW hall floors the right solution for?

LuxTek hall flooring made from PE-HMW/UHMW is particularly suitable for demanding production environments – wherever the floor is exposed to heavy daily loads and downtime is costly:

  • Production and manufacturing halls, including two- and three-shift operations
  • Machine zones with high point loads, such as machine feet and test benches
  • Assembly areas with heavy components and frequent positioning or repositioning
  • Intralogistics and material handling areas within production halls, including pallets, roll containers and pallet trucks
  • Areas exposed to industrial substances such as coolants, oils, greases and cleaning agents
  • Service, maintenance and repair areas subject to impacts and vibrations

FAQ production hall flooring

How much load can LuxTek hall flooring withstand?

Depending on the version, our hall flooring systems are designed for high mechanical loads and can withstand loads of up to 120 tonnes. The key factor is how the load is applied – whether as a distributed load, rolling traffic or point loads such as machine feet. If you provide us with the heaviest load cases, we will recommend the appropriate solution.

Is the hall flooring really suitable for machine feet?

Yes – this is one of the most common applications. Important factors include the machine weight, the contact area of the feet and whether vibrations or movements occur. Based on this information, we design the flooring so that it remains permanently stable in your machine zone.

What is the advantage compared with a coating?

In practice, coatings can be sensitive at edges and transitions – especially under impacts, rolling traffic or contact with industrial substances. Our approach relies on the resistance of the material itself, helping to reduce the risk of layers detaching or being undermined at damaged areas.

How do coolants, oils or cleaning agents affect the flooring?

In many production environments, coolants, oils and cleaning chemicals are part of everyday operations. The hall flooring is designed to resist typical industrial substances. To assess suitability accurately, we briefly review which substances are used, including the medium, temperature and exposure time.

Does LuxTek handle the installation?

Yes, on request we can carry out the implementation on site – from preparation through to professional installation. This gives you a clear process and helps avoid unnecessary interruptions to operations.

Does LuxTek support you with planning and specification?

Yes. We support you with planning – for example with area layout, traffic routes, transitions and specification for point loads and rolling traffic. This ensures that the hall flooring is matched to the actual requirements of your production environment.